Product Overview
▔▔The Vickers DG4V series represents a benchmark in solenoid-operated directional control valves, engineered to direct and stop fluid flow within complex hydraulic systems. Positioned as a premier high-performance solution, the DG4V line is primarily designed for high-pressure, high-flow subplate-mounted configurations.
Key Advantages
▔▔
- High-pressure performance up to 350 bar (5000 psi) with reduced pressure drops.
- Fatigue-resistant cast iron body design ensuring stable spool movement.
- Wet-armature solenoids providing extended service life by eliminating push-rod oil leaks.
- Global standard subplate mounting conforming to ISO 4401-03 and CETOP 3 standards.
Technical Specifications
▔▔
| Technical Parameter | DG4V-3 Standard Series | DG4V-5 High-Performance Series |
| Maximum Operating Pressure (Ports A, B, P) | 350 bar (5000 psi) | 315 bar (4500 psi) |
| Maximum Tank Line Pressure (Port T) | 210 bar (3000 psi) | 160 bar (2300 psi) |
| Maximum Flow Rate | 80 L/min (21 USgpm) | 120 L/min (32 USgpm) |
| Operating Temperature Range | -20 deg C to +70 deg C (-4 deg F to +158 deg F) | -20 deg C to +70 deg C (-4 deg F to +158 deg F) |
| Fluid Viscosity Range | 16 to 360 mm2/s (cSt) | 16 to 360 mm2/s (cSt) |
| Valve Hysteresis | Less than 3% | Less than 3% |
| Response Time (Energized) | 15 to 30 ms | 20 to 45 ms |
| Response Time (De-energized) | 10 to 25 ms | 15 to 35 ms |
| Permissible Fluid Contamination | ISO 4406 Class 18/16/13 | ISO 4406 Class 18/16/13 |
Configuration Options
▔▔
- Valve Construction: 3-way or 4-way direction control, multi-spool center options (Closed Center, Open Center, Tandem, Float).
- Control Method: High-efficiency DC or AC solenoids with manual emergency override buttons.
- Feedback Mechanism: Optional mechanical position switches or inductive proximity sensors for monitoring spool placement in safety circuits.
- Flow Ratings: Multiple flow paths tailored to system requirements (up to 80 L/min for DG4V-3 and 120 L/min for DG4V-5).
- Porting and Mounting Interface: Standardized ISO 4401-03 (NFPA D03) subplate mounting layout.
- Electrical Connection Types: DIN 43650 plug connectors, Deutsch integrated connectors, or terminal box junction leads with optional LED indicator lights.
Key Materials and Components
▔▔
- Valve Body: Precision-cast high-grade ductile iron housing designed to minimize internal distortion under maximum working pressure.
- Internal Spool: Alloy steel spool hardened and precision ground to exact tolerances, reducing internal leakage and preventing spool binding.
- Solenoid Core Tubes: Heavy-duty stainless steel wet-armature tube assembly engineered to withstand continuous internal fluid pressure without flexing.
- Seals and Packing: Premium Fluorocarbon (FKM/Viton) or Nitrile (NBR) dynamic seals ensuring complete media compatibility with synthetic and mineral-based hydraulic oils.
Packaging and Transport Protection
▔▔
- Individual Protection: Each valve undergoes anti-corrosion oil dipping and is sealed in heavy-duty anti-static, moisture-proof polybags with desiccant packets.
- Shock Absorption: Precision-cut foam inserts cushion the valve solenoids and body inside an individual inner cardboard carton.
- Bulk Packaging: Individual cartons are consolidated into reinforced, multi-layer corrugated outer boxes or wooden cases.
- Palletizing and Securing: Boxes are stacked on heat-treated wooden pallets, heat-shrink wrapped, and reinforced with synthetic strapping to prevent movement during export shipping.
Applications
▔▔- Plastic Injection Molding Machines: Controls the precise forward, reverse, and holding sequences of the injection unit and core-pull hydraulic cylinders.
- Metal Stamping Presses: Regulates the main ram directional movements and safety interlock circuits, ensuring fast response times during rapid stamping cycles.
- CNC Machine Tools: Controls hydraulic clamping fixtures, tool changers, and worktable indexing mechanisms demanding zero-drift holding performance.
- Marine Hydraulic Systems: Manages steering gear actuators and winch motor directional shifts, operating reliably under salt-fog and high-vibration conditions.
Related Models
▔▔| Model Code | Description |
| DG4V-3-2A-M-U-H7-60 | ISO 4406 size 03, spring offset spool, 24V DC DIN connector |
| DG4V-3-0C-M-U-H7-60 | ISO 4406 size 03, spring centered spool, 24V DC DIN connector |
| DG4V-3-2N-M-U-G7-60 | ISO 4406 size 03, spring offset spool, 110V AC solenoid |
| DG4V-5-2A-M-U-H7-20 | ISO 4406 size 05, high-flow spring offset spool, 24V DC connection |
| DG4V-5-6C-M-U-H7-20 | ISO 4406 size 05, spring centered tandem spool, 24V DC connection |
| DG4V-3-8C-M-FW-B5-60 | ISO 4406 size 03, spool with flying leads connection, high performance |
FAQ
▔▔Q: How do I decode my Vickers DG4V model code to ensure a direct replacement?
A: Check the metal nameplate located on the side of the valve body. The code indicates the subplate size (e.g., 3 or 5), spool function (e.g., 2A, 0C, 6C), electrical voltage, and design series (e.g., 60 or 20).
Q: What level of oil filtration is required for reliable DG4V operation?
A: We recommend maintaining oil cleanliness at or better than ISO 4406 Class 18/16/13 (typically achieved with a 10-micron nominal inline filter) to prevent spool sticking caused by particulate contamination.
Q: Can DG4V valves operate with water-glycol hydraulic fluids?
A: Yes, provided the valve is configured with Viton (Fluorocarbon) seals and the operating fluid viscosity remains within the 16 to 360 mm2/s (cSt) specification.
Contact Us
▔▔Get in touch with us and we will get in touch with you quickly to give you more personalized information.
Product Overview
▔▔The Vickers DG4V Series represents the industry standard for high-performance, solenoid-operated, direct-acting 4-way directional control valves. Engineered by Eaton Vickers, these valves are designed to direct and stop flow at any point in a hydraulic system, offering unmatched reliability and efficiency in demanding industrial and mobile applications.
Key Advantages
▔▔-
High Flow & Pressure Capability: Delivers exceptional flow rates up to 80 L/min (21 USgpm) and operating pressures up to 350 bar (5075 psi), optimizing system power density.
Low Pressure Drop: Advanced internal flow channel designs minimize pressure losses, reducing heat generation and energy consumption.
Fatigue-Resistant Solenoids: Features wet-armature AC or DC solenoids with easily replaceable coils, ensuring rapid response times, quiet operation, and extremely long service life.
Versatile Spool Configurations: Available in a wide variety of spool types (e.g., closed center, open center, float, tandem) to seamlessly match any hydraulic circuit requirements.
Robust & Weatherproof: Engineered with manual overrides as standard, and IP65/ISO 4400 (DIN connector) electrical connections for reliable operation in harsh environments.
-
Technical Specifications
▔▔| Parameter / Specification | DG4V-3 (Standard Performance) | DG4V-3S (High Performance) |
| Interface Standard | ISO 4401-03, NFPA D03, CETOP 3 | ISO 4401-03, NFPA D03, CETOP 3 |
| Max. Operating Pressure (Ports P, A, B) | 350 bar (5075 psi) | 350 bar (5075 psi) |
| Max. Tank Port Pressure (Port T) | 210 bar (3045 psi) - DC / 160 bar - AC | 210 bar (3045 psi) - DC / 160 bar - AC |
| Max. Flow Rate | Up to 80 L/min (21 USgpm) | Up to 40 L/min (10.5 USgpm) |
| Fluid Temperature Range | -20°C to +70°C (-4°F to +158°F) | -20°C to +70°C (-4°F to +158°F) |
| Viscosity Range | 2.8 to 500 cSt (32 to 2300 SUS) | 2.8 to 500 cSt (32 to 2300 SUS) |
| Recommended Filtration | ISO 4406 Class 20/18/15 or better | ISO 4406 Class 20/18/15 or better |
| Solenoid Voltage Options | 12V DC, 24V DC, 110V AC, 120V AC, 220V AC, 240V AC | 12V DC, 24V DC, 110V AC, 120V AC, 220V AC, 240V AC |
| Protection Class | IP65 (with correct plug fitted) | IP65 (with correct plug fitted) |
Applications
▔▔| Application Field | Machine / System | Key Role of DG4V Valve |
| Industrial Manufacturing | Plastic Injection Molding Machines | Controls clamping, injection, and ejector cylinder movements with precise timing. |
| Metalworking & Pressing | Hydraulic Pressing & Shearing Machines | Manages high-pressure ram descent, hold, and rapid retraction cycles. |
| Mobile & Construction Equipment | Aerial Work Platforms & Cranes | Directs fluid to outriggers and boom lift cylinders, ensuring smooth and safe operations. |
| Marine & Offshore | Winches & Deck Machinery | Drives hydraulic motors for anchor handling and cargo winches in corrosive maritime environments. |
| Power Generation | Turbine Governor Systems & Wind Turbines | Regulates auxiliary hydraulic acts such as blade pitch control and safety braking systems. |
Related Models
▔▔| Model Code Segment | Options / Indicators | Description |
| DG4V-3(S) | Base Model Designation | Directional Valve, Gasket mounted, Solenoid operated, 4-way, 3 size (or 3S high-performance) |
| Spool Type | 0, 2, 6, 7, 8, 22, 33 (e.g., DG4V-3-2C) | 0: Open center; 2: Closed center; 6: Float center; 8: Tandem center |
| Spool Spring Arrangement | A, B, C, F, N | A: Spring offset; B: Spring centered (1 solenoid); C: Spring centered (2 solenoids); F: Detented |
| Solenoid Type | W, WA, WB | W: Wet armature (DIN connector connection style) |
| Voltage Code | G, H, B, D | G: 12V DC; H: 24V DC; B: 110V AC 50Hz / 120V AC 60Hz; D: 220V AC 50Hz / 240V AC 60Hz |
| Design Number | 60, 61, 62 | Subject to change. Standard current release is the 60 series. |
FAQ
▔▔Q1: What is the difference between DG4V-3 and DG4V-3S?
A: The DG4V-3 is the standard version optimized for high flow capacity (up to 80 L/min), whereas the DG4V-3S is a high-performance/solenoid-efficient version designed for standard duty cycles and lower maximum flows (up to 40 L/min), offering lower power consumption and optimized cost-performance.
Q2: Can I replace an AC solenoid coil with a DC solenoid coil on the same valve?
A: No, you cannot simply swap AC and DC coils on the same armature tube. The physical size, coil resistance, and armature stroke configurations differ between AC and DC versions. To change the voltage type, you generally need to change the entire solenoid tube/coil assembly specified for that voltage, or order the matching valve model.